Product Introduction
The ECNITY DC direct drive centrifugal blower consist primarily of a brushless DC motor, single-inlet impeller, volute housing, and an external speed controller. The simple structure and reduced number of components result in a low failure rate. The brushless DC motor uses permanent magnets, eliminating excitation losses and significantly improving efficiency compared to brushed DC motors, while avoiding brush wear. Impellers are typically made of galvanized steel or engineering plastics, offering corrosion resistance and low weight. The compact volute design closely follows the airflow trajectory, reducing leakage and improving air delivery efficiency. External speed controllers provide basic speed adjustment but do not support constant pressure or constant airflow control, making them suitable for basic ventilation applications.

DC direct drive centrifugal blower technical parameters:
|
Model No. |
Rated |
Operation Voltage |
Rated |
Rated |
Rated |
Air Flow |
Air |
Noise |
|
VDC |
VDC |
A |
W |
RPM |
m3/h |
Pa |
dBA |
|
|
EN-F120-H062-D024-A01 |
24 |
18~32 |
2.50 |
60 |
2400 |
280 |
350 |
58 |
|
EN-S120-H062-D024-A01 |
||||||||
|
EN-F120-H062-D048-A01 |
48 |
36~57 |
1.25 |
60 |
2400 |
280 |
350 |
58 |
|
EN-S120-H062-D048-A01 |
Outline Drawing:

Performance Curve

Connection
|
DC Wire |
|
|
Color |
Function |
|
Red |
024 / 048VDC |
|
Blue |
GND |
|
Yellow |
0~10VDC/PWM |
|
White |
FG |
Case of DC direct drive centrifugal blower: Small Warehouse Basic Ventilation
An 80 m² hardware storage room required basic ventilation to remove humidity and light dust. Two DC single-inlet centrifugal blowers with airflow of 1000 CFM and static pressure of 0.8 PSI were installed using floor mounting.
Speed was adjusted via external rotary controllers, requiring no specialized training. Maintenance involved monthly cleaning and semiannual inspection. After two years of operation, only one speed controller was replaced at minimal cost, fully meeting basic ventilation needs.

Our factory


















FAQ
1. Are forward curved fans sensitive to voltage fluctuation?
EC and DC versions are less sensitive to voltage fluctuation due to built-in electronic control.
2. Can forward curved fans support smart control systems?
Yes. EC models can be integrated with smart controllers and building management systems.
3. Are forward curved fans suitable for air curtain units?
In some air curtain designs, forward curved fans are used for compact airflow solutions.