Product Introduction
Control of the DC Exhaust centrifugal blower is relatively simple, relying mainly on external PWM controllers or voltage regulation. Speed control range is limited and does not support constant airflow or pressure control. The simple control signal reduces cost and complexity, making these blowers suitable for basic applications. However, they do not support remote communication or intelligent system integration, requiring manual on-site adjustment. Electrical noise is higher, and protection functions are limited, typically offering only basic thermal protection.

DC Exhaust centrifugal blower technical parameters:
|
Model No. |
Rated |
Operation Voltage |
Rated |
Rated |
Rated |
Air Flow |
Air |
Noise |
|
VDC |
VDC |
A |
W |
RPM |
m3/h |
Pa |
dBA |
|
|
EN-F140-H059-D024-B01 |
24 |
18~32 |
5.00 |
120 |
2250 |
450 |
460 |
68 |
|
EN-S140-H059-D024-B01 |
||||||||
|
EN-F140-H059-D048-B01 |
48 |
36~57 |
2.50 |
120 |
2250 |
450 |
460 |
68 |
|
EN-S140-H059-D048-B01 |
||||||||
|
EN-F140-H059-D024-B02 |
24 |
18~32 |
5.80 |
140 |
2650 |
590 |
600 |
72 |
|
EN-S140-H059-D024-B02 |
||||||||
|
EN-F140-H059-D048-B02 |
48 |
36~57 |
2.90 |
140 |
2650 |
590 |
600 |
72 |
|
EN-S140-H059-D048-B02 |
Outline Drawing:

Performance Curve

Connection
|
DC Wire |
|
|
Color |
Function |
|
Red |
024 / 048VDC |
|
Blue |
GND |
|
Yellow |
0~10VDC/PWM |
|
White |
FG |
The DC Exhaust centrifugal blower offers high starting torque, fast speed response, and excellent low-speed torque performance, meeting airflow adjustment needs across different applications. With lower manufacturing costs, they provide strong cost performance. However, compared with EC models, DC blowers have simpler control methods, slightly higher electrical noise, and lower efficiency. They are mainly used in small household appliances, telecom equipment cooling, and compact ventilation systems where control precision requirements are low.

Our factory


















FAQ
1. Do forward curved fans require special installation tools?
Standard installation tools are usually sufficient. Following manufacturer guidelines ensures proper operation.
2. Can forward curved fans be used in heat recovery systems?
Yes. They are commonly used in ventilation and heat recovery units with moderate airflow demand.
3. Are forward curved fans affected by airflow blockage?
Severe blockage can reduce efficiency and increase noise. Proper system design helps avoid such issues.
4. Are forward curved fans suitable for low-pressure duct systems?
Yes. They perform well in low-pressure ducted ventilation systems.