Product Introduction
The ECNITY EC High airflow centrifugal fans are predominantly used in high-end, high-demand applications, leveraging their intelligence, precision, stability, energy efficiency, and environmental resilience. They are ideal for commercial complexes, precision laboratories, advanced industrial facilities, and premium residential projects, offering excellent long-term cost performance.

EC High airflow centrifugal fan technical parameters:
|
Model No. |
Rated |
Operation Voltage |
Frequency |
Rated |
Rated Power |
Rated |
Air Flow |
Air |
Noise |
|
VAC |
VAC |
Hz |
A |
W |
RPM |
m3/h |
Pa |
dBA |
|
|
EN-F180-H094-E115-B01 |
115 |
90~135 |
50/60 |
2.70 |
180 |
1600 |
1300 |
470 |
70 |
|
EN-S180-H094-E115-B01 |
|||||||||
|
EN-F180-H094-E230-B01 |
230 |
184~274 |
50/60 |
1.35 |
180 |
1600 |
1300 |
470 |
70 |
|
EN-S180-H094-E230-B01 |
Outline Drawing:

Performance Curve

Connection
|
DC Wire |
AC Wire |
||
|
Color |
Function |
Color |
Function |
|
Red |
+10VDC |
Brown |
L |
|
Blue |
GND |
Blue |
N |
|
Yellow |
0~10VDC/PWM |
Green/Yellow |
PE |
|
White |
FG |
||
Case of EC High airflow centrifugal fan: Large Commercial Complex Fresh Air System
A 120,000 m² commercial complex in a city center integrates shopping malls, supermarkets, restaurants, and cinemas, requiring complex ventilation, 24-hour continuous operation, and high standards for noise, energy efficiency, and intelligent control. The project deployed 86 EC single-inlet centrifugal blowers tailored to different zones. Public areas used models with airflow of 1500–2500 CFM and static pressure of 2.8 PSI, integrated with the building automation system via RS485 communication to dynamically adjust speed based on CO₂ concentration and occupancy.
Dining areas used IP54-rated, corrosion-resistant models to withstand grease and humidity, while cinema areas adopted low-noise models (≤45 dB) with soft-start functionality to minimize startup noise.
After commissioning, the system reduced annual electricity costs by approximately RMB 320,000 compared with traditional AC fans. The failure rate remained below 0.8%, and only monthly impeller cleaning was required, fully meeting the long-term, high-demand ventilation requirements of commercial complexes.

Our factory


















FAQ
1. Can EC fans be used in air handling units (AHUs)?
Yes, EC centrifugal fans are commonly used in air handling units. They provide stable airflow and high static pressure capability. Integrated control allows easy airflow adjustment. EC fans help improve overall AHU energy efficiency.
2. Can EC centrifugal fans restart automatically after a power failure?
Many EC fans can restart automatically after power is restored. Restart behavior depends on controller settings. This feature is useful for unattended systems. Restart characteristics should be confirmed for each model.
3. Can EC centrifugal fans operate without airflow sensors?
Yes, EC fans can operate without airflow sensors. Speed is controlled directly by input signals. Sensors may be added for closed-loop control if required. Sensor use depends on system design.