Product Introduction
The ECNITY EC centrifugal fan for kitchen exhaust offer flexible load adaptability, supporting constant-resistance, variable-resistance, and impact loads. Intelligent control automatically adjusts speed to maintain stable airflow and static pressure under changing system resistance. In the event of sudden load shocks - such as duct blockage or airflow surges - the system responds rapidly to prevent motor overload or equipment damage.

EC centrifugal fan for kitchen exhaust technical parameters:
|
Model No. |
Rated |
Operation Voltage |
Frequency |
Rated |
Rated Power |
Rated |
Air Flow |
Air |
Noise |
|
VAC |
VAC |
Hz |
A |
W |
RPM |
m3/h |
Pa |
dBA |
|
|
EN-F133-H042-E115-A01 |
115 |
90~135 |
50/60 |
1.00 |
65 |
2350 |
280 |
350 |
60 |
|
EN-S133-H042-E115-A01 |
|||||||||
|
EN-F133-H042-E230-A01 |
230 |
184~274 |
50/60 |
0.50 |
65 |
2350 |
280 |
350 |
60 |
|
EN-S133-H042-E230-A01 |
Outline Drawing:

Performance Curve

Connection
|
DC Wire |
AC Wire |
||
|
Color |
Function |
Color |
Function |
|
Red |
+10VDC |
Brown |
L |
|
Blue |
GND |
Blue |
N |
|
Yellow |
0~10VDC/PWM |
Green/Yellow |
PE |
|
White |
FG |
||
The ECNITY EC centrifugal fan for kitchen exhaust offer strong cable adaptability. Power cables support 1.5~4 mm² copper conductors, while communication cables support 0.75~1.5 mm² shielded cables, allowing installation distances of up to 100 meters without significant voltage drop or signal distortion. Cable interfaces feature waterproof and corrosion-resistant designs, ensuring reliable operation in outdoor, dusty, or humid environments.
The ECNITY EC centrifugal fan for kitchen exhaust demonstrate excellent tolerance to frequent start–stop cycles, supporting 50~100 start–stop operations per day without noticeable mechanical impact. This makes them ideal for applications requiring frequent cycling, such as laboratory ventilation, intermittent equipment cooling, and emergency ventilation. Soft-start and soft-stop functions eliminate inrush current and airflow fluctuations during operation changes. The intelligent controller records start–stop counts and operating hours, enabling maintenance personnel to assess wear conditions and optimize service intervals, thereby extending overall service life.

Our factory


















FAQ
1. What are common misconceptions about EC fan reliability?
Some believe integrated electronics reduce reliability. In practice, EC fans include protection features. Reduced mechanical wear improves durability. Proper environment and installation are key.
2. Do EC fans generate more electromagnetic interference (EMI)?
EC fans are designed to meet standard EMI requirements. Proper grounding minimizes interference. Installation quality affects EMI performance. Compliance should be confirmed for sensitive applications.
3. Are EC fans difficult to control or integrate into systems?
EC fans are generally easy to integrate. Standard control signals are commonly supported. Integrated control reduces system complexity. Control requirements should be clarified during selection.