Ec Backward Centrifugal Exhaust Fan

Ec Backward Centrifugal Exhaust Fan

Motor type: BLDC external rotor motor
Impeller Diameter: 280mm
Impeller Material: PA66
Direction of Rotation: CW, see on rotor
Speed Control: 0-10VDC/PWM
Type of Protection: IP44 / IP54
Insulation Class: B
Operation Mode: S1
Bearing: Maintenance-free ball bearing
Ambient Temperature: -25~+60℃
Motor Protection: Locked-Rotor Protection, Reverse Polarity Protection, Thermal Protection, Soft Start
Certificate: CE, LVD, ROHS, ETL
Send Inquiry
Description
Technical Parameters

Product Introduction

Intelligent control is one of the core advantages of ECNITY EC backward centrifugal exhaust fan. The fan integrates an advanced electronic control module that can be directly connected to Building Management Systems (BMS), enabling remote monitoring, debugging, and fault feedback without on-site manual operation. This significantly reduces maintenance and operation costs.

The EC motor includes integrated power conversion capability and can be directly connected to 115V / 220V single-phase power or 380V three-phase power, with frequency compatibility of 50/60 Hz. No additional transformer is required, simplifying installation.

Speed regulation accuracy reaches ±1%, allowing the fan to automatically adjust its operating status according to environmental parameters such as temperature, humidity, and pressure. This demand-based airflow supply helps avoid unnecessary energy consumption.

The fan also provides speed feedback signals, enabling real-time monitoring of operating speed. Additionally, a soft-start function ensures smooth startup currents, preventing sudden current surges that could impact the power grid. This makes the fan particularly suitable for commercial buildings, data centers, and other environments requiring stable power supply.

product-800-800

Ec backward centrifugal exhaust fan technical parameters:

 

Model No.

Rated
Voltage

Operation Voltage

Frequency

Rated
Current

Rated Power

Rated
Speed

Air Flow

Air
Pressure

Noise
Level

VAC

VAC

Hz

A

W

RPM

m3/h

Pa

dBA

EN-B280-H093-E115-C01

115

90~135

50/60

4.00

450

2830

3450

965

79

EN-B280-H093-E230-C01

230

184~274

50/60

2.00

450

2830

3450

965

79

EN-B280-H093-E380-C01

380

310~460

50/60

1.20

450

2830

3450

965

79

 

Outline Drawing:

 

product-1414-663

Performance Curve

 

product-754-499

Connection

 

DC Wire

AC Wire

Color

Function

Color

Function

Red

+10VDC

Brown

L

Blue

GND

Blue

N

Yellow

0~10VDC/PWM

Green/Yellow

PE

White

FG

 

Compared with traditional AC centrifugal fans, Ec backward centrifugal exhaust fan offer significant energy-saving benefits. The EC motor utilizes permanent magnets combined with electronic commutation technology, eliminating rotor electrical losses found in traditional AC motors. Overall system efficiency can reach up to 90%, providing 30–50% energy savings.

For example, a 500W industrial fan operating 8 hours per day can save nearly thousands of yuan in electricity costs annually, achieving a return on investment within 3–6 months.

The fan's demand-based speed control ensures that when ventilation demand decreases, the motor automatically reduces speed, minimizing energy consumption and avoiding the traditional "full-speed operation with throttling control" waste pattern.

 

1Product details

 

Our factory

 

product-1000-1000
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-1080-1080
workshop
product-1276-1276
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-1280-1280
workshop
product-1276-1276
workshop
product-800-800
workshop
product-1276-1276
workshop

 

2Typical Applications

4Package and Transportation

 

FAQ

1. Are EC fans suitable for industrial exhaust hoods?

EC centrifugal fans are suitable for industrial exhaust hoods. They can handle duct resistance and varying airflow demand. Speed control helps optimize exhaust performance. Correct sizing is important for safety.

2. Can EC fans be used in make-up air systems?

EC fans are used in make-up air systems to supply fresh air. Adjustable airflow supports balanced ventilation. High efficiency reduces operating costs. Integration with control systems is common.

3. Can EC fans be applied in clean air ventilation systems?

Yes, EC fans are used in clean air ventilation systems. Smooth speed control supports stable airflow. They are suitable for systems with filters. Application requirements should be clearly defined.

4. Are EC fans suitable for air filtration systems?

EC centrifugal fans are commonly used in air filtration systems. They can overcome pressure loss caused by filters. Speed can be adjusted as filter resistance increases. This helps maintain consistent airflow.

 

Hot Tags: ec backward centrifugal exhaust fan, China ec backward centrifugal exhaust fan manufacturers, suppliers, factory, high efficiency EC fan, EC Smart Ventilation Fan, cooling fan for power electronics, EC Centrifugal Fan Hvac, fan for heat exchanger, centrifugal kitchen extractor fan