133mm EC Double Inlet Centrifugal Fan

133mm EC Double Inlet Centrifugal Fan

Motor type: BLDC external rotor motor
Impeller Diameter: 133*190mm
Impeller Material: Galvanized Metal Steel
Direction of Rotation: CW, see on rotor
Speed Control: 0-10VDC/PWM
Type of Protection: IP44 / IP54
Insulation Class: B
Operation Mode: S1
Bearing: Maintenance-free ball bearing
Ambient Temperature: -25~+60℃
Motor Protection: Locked-Rotor Protection, Reverse Polarity Protection, Thermal Protection, Soft Start
Certificate: CE, LVD, ROHS, ETL
Send Inquiry
Description
Technical Parameters

Product Introduction

The ECNITY 133mm EC Double inlet centrifugal fan is based on Electronically Commutated (EC) technology, combining the convenience of AC power supply with the high efficiency of DC motor operation. It represents a new generation of ventilation equipment that balances energy efficiency and intelligent control.

Featuring a symmetrical double-inlet design, the inlet area is effectively doubled compared to single-inlet models. This allows air to enter the impeller more evenly, significantly reducing energy losses caused by airflow turbulence while simultaneously lowering vibration and noise. The motor adopts permanent magnet synchronous technology and operates without mechanical carbon brushes, achieving an energy conversion efficiency of over 90% and delivering 30–70% energy savings compared with traditional fans. The blower fully complies with stringent global energy efficiency regulations such as the EU ErP Directive.

product-800-800

133mm EC Double inlet centrifugal fan technical parameters:

 

Model No.

Rated
Voltage

Operation Voltage

Frequency

Rated
Current

Rated Power

Rated
Speed

Air Flow

Air
Pressure

Noise
Level

VAC

VAC

Hz

A

W

RPM

m3/h

Pa

dBA

EN-D133-H190-E115-A01

115

90~135

50/60

1.80

120

1400

900

290

67

EN-D133-H190-E230-A01

230

184~274

50/60

0.90

120

1400

900

290

67

 

Outline Drawing:

 

product-1474-814

Performance Curve

 

product-840-580

Connection

 

DC Wire

AC Wire

Color

Function

Color

Function

Red

+10VDC

Brown

L

Blue

GND

Blue

N

Yellow

0~10VDC/PWM

Green/Yellow

PE

White

FG

 

An integrated intelligent control module supports 0–10 V / PWM analog control as well as MODBUS digital communication, enabling dynamic speed adjustment according to real-time load conditions. This allows precise matching of airflow and static pressure requirements. 133mm EC double inlet centrifugal fan blowers are widely used in central HVAC systems for commercial complexes, industrial workshop ventilation, and other medium- to large-scale applications.

 

From a fundamental perspective, the key advantage of 133mm EC double inlet centrifugal fan lies in electronic commutation technology, forming an integrated system of "AC input – DC drive – intelligent control." Grid AC power is internally converted to DC, and electronic circuitry precisely controls motor commutation and speed. Stepless speed regulation is achieved without an external frequency inverter, reducing additional energy losses.

DC double inlet centrifugal blowers rely on the electromagnetic induction principle of DC motors. DC current generates a constant magnetic field that drives rotor rotation and impeller motion. Brushed models use mechanical carbon brushes for commutation, while brushless models rely on Hall sensors or sensorless vector control. Their simpler structure and control logic make them suitable for basic ventilation applications with lower speed-control precision requirements.

 

product-850-850

 

Our factory

 

product-1000-1000
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-1080-1080
workshop
product-1276-1276
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-1280-1280
workshop
product-1276-1276
workshop
product-800-800
workshop
product-1276-1276
workshop

 

2Typical Applications

4Package and Transportation

 

FAQ

1. Can EC fans be used in residential ventilation systems?

EC fans can be used in residential ventilation systems. Quiet operation and speed control improve comfort. Energy efficiency supports long-term operation. Selection should match system size.

2. Are EC fans suitable for OEM ventilation equipment?

EC fans are widely used in OEM ventilation equipment. Compact design simplifies integration. Integrated control reduces external components. This supports standardized OEM production.

3. Can EC centrifugal fans be used in industrial process cooling?

EC centrifugal fans are suitable for industrial process cooling. They provide reliable airflow under continuous operation. Speed control allows adaptation to process demand. Proper specification ensures stable cooling performance.

4. Are EC fans suitable for laboratory ventilation systems?

EC fans are used in laboratory ventilation systems when properly specified. Stable airflow control supports safety requirements. They can be integrated with monitoring systems. Application conditions must be clearly defined.

 

Hot Tags: 133mm ec double inlet centrifugal fan, China 133mm ec double inlet centrifugal fan manufacturers, suppliers, factory, centrifugal fans and blowers, 150mm Double Inlet Ec Centrifugal Blower, double inlet blower fan, 133mm EC Double Inlet Centrifugal Fan, dual inlet blower fan, double inlet blower