DC Quiet Low Pressure Centrifugal Blower

DC Quiet Low Pressure Centrifugal Blower

Motor type: BLDC external rotor motor
Impeller Diameter: 140mm
Impeller Material: Galvanized Metal Sheet
Direction of Rotation: CW, see on rotor
Speed Control: 0-10VDC/PWM
Type of Protection: IP44 / IP54
Insulation Class: B
Operation Mode: S1
Bearing: Maintenance-free ball bearing
Ambient Temperature: -25~+60℃
Motor Protection: Locked-Rotor Protection, Reverse Polarity Protection, Thermal Protection, Soft Start
Certificate: CE, LVD, ROHS, ETL
Send Inquiry
Description
Technical Parameters

Product Introduction

The ECNITY DC quiet low pressure centrifugal blower are limited in load adaptability. Brushless DC models can handle constant or mildly variable loads but cannot respond quickly to large fluctuations, risking overload or pressure spikes. Brushed DC models support only fixed constant loads; any load change leads to speed drop and insufficient airflow, restricting use to basic, stable-load applications.

product-800-800

DC quiet low pressure centrifugal blower technical parameters:

 

Model No.

Rated
Voltage

Operation Voltage

Rated
Current

Rated
Power

Rated
Speed

Air Flow

Air
Pressure

Noise
Level

VDC

VDC

A

W

RPM

m3/h

Pa

dBA

EN-F140-H059-D024-A01

24

18~32

3.30

80

1800

420

350

63

EN-S140-H059-D024-A01

EN-F140-H059-D048-A01

48

36~57

1.65

80

1800

420

350

63

EN-S140-H059-D048-A01

 

Outline Drawing:

 

product-1550-582

Performance Curve

 

product-819-513

Connection

 

DC Wire

Color

Function

Red

024 / 048VDC

Blue

GND

Yellow

0~10VDC/PWM

White

FG

 

The DC quiet low pressure centrifugal blower perform poorly at low temperatures. Brushless DC models require 5–10 minutes of preheating at –10°C and achieve only about 80% start success. Brushed DC models often fail to start below 0°C due to coil icing and poor brush contact, making them unsuitable for cold or outdoor applications.

 

product-850-850

 

Our factory

 

product-1000-1000
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-800-800
workshop
product-1080-1080
workshop
product-1276-1276
workshop
product-1200-1200
workshop
product-1280-1280
workshop
product-1280-1280
workshop
product-1276-1276
workshop
product-800-800
workshop
product-1276-1276
workshop

 

2Typical Applications

4Package and Transportation

 

FAQ

1.Are forward curved fans suitable for air filtration units?

Yes. They are commonly used in filtration and air purification equipment where moderate pressure and steady airflow are required.

2.What mounting orientations are supported?

Forward curved centrifugal fans can typically be installed in multiple orientations depending on housing design. Installation guidelines should be followed to ensure performance.

3.Can forward curved fans operate at variable speeds?

Yes. Variable speed operation is a key advantage, especially with EC motors. It helps optimize airflow and energy consumption.

4.Are forward curved fans easy to maintain?

Maintenance is relatively simple. Regular inspection and cleaning help maintain airflow performance and extend service life.

 